Electronic Temperature Instruments Driver



If you cannot find an instrument driver that supports your Application Development Environment (ADE), use an instrument driver converter: The LabVIEW Instrument Driver Import Wizard allows you to convert an instrument driver from LabWindows/CVI (C source) to a LabVIEW wrapper (DLL). The LabVIEW Instrument Driver Export Wizard allows you to. La Crosse Technology 302-604B Indoor Temperature & Humidity Station, Black is the most popular La Crosse Technology Weather Instrument with 8 reviews and starting at $29.99. La Crosse Technology 308-146 Wireless Color Forecast Station with USB charging port is the most popular La Crosse Technology Weather Instrument with 6 reviews and starting.

New ProductsElectronic temperature instruments driver test

Electronic Temperature Instruments Driver Download

Electronic Temperature Instruments DriverDriverElectronic

Electronic Temperature Instruments Driver Test

The LFI3751 with Autotune PID is a high-performance temperature control instrument. Drive up to ±5 A to either thermoelectrics (TECs) or resistive heaters (RH) with up to 8 V compliance. This instrument operates from AC (115 / 230, 50 or 60Hz). Expect stability as good as 0.001°C with thermistors. The TMP117 is a high-precision digital temperature sensor. It is designed to meet ASTM E1112 and ISO 80601 requirements for electronic patient thermometers. The TMP117 provides a 16-bit temperature result with a resolution of 0.0078°C and an accuracy of up to ±0.1°C across the temperature range of -20°C to 50°C with no calibration. Electronic Temperature Instruments Limited (ETI) is a worldwide manufacturer and distributor of thermometers and portable test and measurement instrumentation. ETI supplies catering, industrial, HVAC, wireless, legionnaires, refrigeration thermometers and environmental monitoring instruments to various industries.

Electronic Temperature Instruments Driver Combo

  • TES-3250

    COLOR METER

    • Large LCD Display、Easy to use
    • Check the color difference between two samples
    • Economical, Portable and easy to use
    • Color difference displayed Δ(L*,a*,b*), Δ(E*ab,
      C*ab, H*ab), Δ(Y, x, y), Δ(X, Y, Z), Δ(Rs, Gs, Bs) or
      Δ(WI, YI, Tw)
    • Color space displayed (L*, a*, b*), (L*, C*ab, hab),
      (Y, x, y), (X, Y, Z), (Rs, Gs, Bs) or (WI, YI, Tw)
    • Statistical function (Maximum, Minimum, Average and
      Standard Deviation)
    • Color difference tolerance set to perform PASS/WARN/FAIL
    • Store 9 color – difference target colors
    • User calibration function ensures higher accuracy
    • Auto memory (99 sets) & Read function
    • Auto Power off function
    • LCD backlight function
    • Mini-USB interface.
  • TES-3260

    Infrared Thermometer

    • Large LCD Display、Easy to use
    • ℃ / ℉ Selectable
    • Backlight LCD display
    • Laser targeting
    • Auto Hold function
    • Maximum/Minimum reading recorder function
    • Data memory and read function
    • Auto-Power off function
    • User temperature calibration function
  • TES-3145 / TES-3145U

    Anemometer

    • Air flow volume
    • Instant/Avg/2/3 V max flow measurement
    • Velocity m/s, f t/min
    • Temperature, Humidity & Atmospheric measurement
    • Calculate Dew point temperature, Wet bulb
      temperature, Wind chill temperature, Humidex
      temperature and Heat index temperature.
    • Data hold & Maximum/Minimum/Average function
    • Manual data memory and read function: 99 sets
    • Auto data memory: 4GB microSD card (3145U)
    • USB interface (3145U)
  • TES-1389 / TES-1389U

    BRIX METER

    • Personal dietary sugar content confirmation
    • Food industry:
      Beverages, fruits and sweets
    • Industry:
      Monitoring of lubricants in machines and quality control
    • Agriculture:
      Determination of the degree of ripeness of fruit for quality control in harvesting
    • Wide measuring range (Brix 0 ~ 53%)
    • Refractive index measurement (RI)
    • Temperature measurement (°C/°F)
    • Ambient temperature compensation (ATC)
    • Brix or RI high/low limit value alarm function
    • Zero calibration with distilled or deionized water
    • Friendly operation and easy to use
    • Wide and dual display LCD and backlight function
    • Reliable water resistant (IP65)
    • Auto power off function
    • Data memory and read function
    • Auto data logger function (1389U)
    • USB Interface (1389U)
  • TES-3196

    AC/DC Gauss Meter

    • Use a uniaxial Hall effect transverse probe with automatic temperature compensation
    • User select Gauss, Tesla or Ampere/Meter readings
    • DC Zero function & AC Trms measurement
    • Data Hold & Maximum/Minimum record function
    • Relative & Alarm High/Low limit function
    • X, Y and Z axis vector summing function
    • LCD backlight & auto power off function
    • Manual memory stores up to 99 data
      APPLICATIONS
    • DC magnetic field meter measuring static magnetic strength
    • AC magnetic field meter measuring the wave motion of the electromagnetic field (EMF)
    • After machine component are processed, remain the magnetism to measurement
    • Magnetic force measurement of the magnetisable material
    • Magnetic application products, the intensity of magnetic field measurement
    • Electrical home appliances products, the magnetic field intensity measurement of the motor
    • Exceed the leakage magnetic field of conducting the magnetite to measure
    • Magnetic field intensity measurement of the permanent magnet
    • Various steel products brought magnetic measurement naturally
  • TES-3142 / TES-3142U

    Pitot Tube Anemometer & Differential Pressure Manometer

    • Air flow volume
    • Differential pressure, Stagnation pressure and
      Static pressure measurement
    • Instant/Avg/ 2/3 V max flow measurement
    • Velocity m/s, f t/min
    • Temperature, Humidity & Atmospheric measurement
    • Calculate Dew point temperature, Wet bulb
      temperature, Wind chill temperature, Humidex
      temperature and Heat index temperature.
    • Data hold & Maximum / Minimum / Average function
    • Manual data memory and read function: 99 sets
    • Auto data memory: 4GB microSD card (3142U)
    • USB interface (3142U)
  • TES-1386/TES-1386U

    TURBIDITY METER

    • Water Quality Testing
    • Test Tap Water
    • Food and Beverage water
    • Other related water quality testing
    • Auto-ranging from 0 to 1000 NTU (Nephelometric Turbidity Unit)
    • Waterproof and dustproof with IP65-rated housing that floats
    • Meets performance criteria as specified by ISO 7027
      (DIN EN 27027) method
    • Low battery alarm and auto shut off after 10 minutes of non use
    • Large LCD display and backlight function
    • Four point calibration for full-range accuracy
    • Maximum/minimum, alarm and relative function
    • Manual data memory and read function
    • Auto data logger function (1386U)
    • USB interface (1386U)
  • PROVA 136

    Temperature Calibrator (RTD + TC)

    • High precision and combination of RTD and Thermocouple (TC) calibration
    • Source and measure 14 types of RTD and resistance
    • Source and measure 11 types of thermocouples (TC)
    • 4W, 3W, and 2W connections for RTD simulation and measurement
    • Current calibration of 4 fixed values (100μA, 250μA, 1mA, and 2mA)
    • ℃ and ℉ selectable
    • Accept wide range of excitation current (0.05mA to 5mA) for RTD simulation
    • Individual cold junction compensation (CJC) for simulation and measurement of thermocouples. CJC can be used to fine tune temperature calibration.
    • Easy 0% and 100% setup and operation
    • Easy 25%▲ (up) and 25▼ (down) for temperature calibration.
    • Individual memory of 0% and 100% setup for different RTD types and thermocouple types
    • Auto step and auto ramp for easy linear calibration
    • Detection of too low or too high excitation current (LO or HI) from the measurement device
    • Warning of exceeding calibrator driving current (IEX)
    • Memory of last setup when power off
    • Easy numerical keypad for input
    • Dot Matrix LCD with backlight
    • Very low power consumption of 30mA with backlight off
    • 15 minutes smart auto-power-off. 15 minutes timer resets itself when any input changes
    • 2 minutes smart auto-backlight-off. 2 minutes timer resets itself when any input changes
  • PROVA - A9

    AC/DC TRMS Mini Clamp Meter

    • Accurate AC/DC digital clamp meter
    • Best accuracy ±1.5%±3dgts
    • AC 1mA, DC 10mA high resolution
    • True RMS measurement
    • One touch zero (Δ) for DCA adjustment
    • 25 mm diameter jaws
    • Fast bar graph display (30 times/sec.) for transient observation
    • In-Rush Current Measurement with 100mS integration time
    • Non-Contact Frequency Measurement (min. sensitivity 0.06 AC A)
    • Non-Contact Voltage (NCV) Detection from 80V to 600V at 50/60Hz
    • Low Pass Filter (LPF) at 1 KHz Cut-off Frequency
    • Large 3 3/4 digits LCD
    • Data Hold function
    • 15 minutes auto-power-off with beeping warning before turning off
    • Backlight with 5 minutes of auto-backlight-off
    • Easy single rotary switch for any function selection
    • Ideal for works in crowded switch box or cable areas
  • SP-500

    Integrating Sphere

    • 500mm internal sphere (includes a lamp holder, baffles, and ports for photometers)
    • Light weight and easy move
      APPLICATIONS:
    • As a light collector
    • As uniform light source
    • Luminance/Radiance calibration
    • Reflectance measurement (Color measurement Fluorescence spectroscopy)
    • Beam Power measurement (total power of a beam of optical radiation)
    • Lamp Flue measurement (total geometric luminous flux of a light source)
    • Laser Power measurement
    • IR Reflectance measurement
    • Irradiance measurement (Laser, LED, and Halogen lamps)
  • PROVA-135

    4-20mA Loop Calibrator + Thermometer

    • Source 4~20mA, 0~24mA with 1μA resolution (1KΩ load, 24V loop supply), basic accuracy 0.025%.
    • Source 0~24.000V with 1mV resolution.
    • Source frequency 1~20000Hz square wave with programmable duty cycle (1~99%).
    • Auto step and auto ramp for sourcing mA, V.
    • Easy fixed 25% up and down, or programmable percentage (1~99%) increase and decrease (mA, V).
    • Measure DC mA with loop power (24V output).
    • Measure DC V.
    • Measure Temperature (°C, °F) of 11 types of thermocouples (K, J, E, T, R, S, N, L, U, B and C).
    • Calibrator grade precision temperature measurement with 0.1*C & 0.1*F resolution.
    • Detection of thermocouples disconnection.
    • Source and Measure at the same time.
    • Warning for overload, output open (mA) or short (V).
    • Short circuit protection for output.
    • Battery power indication (%) when turn on the calibrator.
      Applications:
    • Calibration of 4~20mA panel meters.
    • LED brightness testing (0~24mA).
    • Temperature calibration of panel meters or instruments for 11 types of thermocouples.
  • PROVA - A11

    mA AC/DC Clamp Meter

    • Very high resolution DC 1mA, AC 0.1mA.
    • AC/DC (mA, A) current measurement: 6A / 60A.
    • AC/DC (V) voltage measurement: 60V / 600V.
    • AC current measurement: TRMS.
    • Resistance, Continuity, Capacitance, Diode and Temperature (℃/℉) measurement.
    • Voltage/Current Peak value measurement.
    • 6000 counts
    • Auto and Manual ranges for AC mA, AC/DC V, Resistance and Capacitance.
    • One Touch Zero for DCA adjustment.
    • 25mm large jaw diameter.
    • Auto-power-off function (30 min.) and Backlight.
    • Delta ( ) functions w.r.t. hold value.
    • Dual display: Hold + Ave, Max + Min,ΔMax +ΔMin.
    • Dual display (peak hold): Hold + Ave, Peak Max + Peak Min,ΔPeak Max +ΔPeak Min.
    • Low Pass Filter (LPF, 1KHz, -3dB) (e.g. for VFD measurement)
    • 600V overload protection for Resistance and Capacitance measurement.
    • Ideal for works in crowded switch box or cable areas.
  • TES-3079M

    HVAC Trms Clamp Meter (1000A)

    • 10 in 1 multifunction clamp meter
    • Voltage, Current, Power, Horse power, Reactive power, Apparent power, Phase angle, Frequency, Power factor, Phase sequence, Temperature, Resistance, Capacitance, Diode
    • Trms reading/Dual display/Auto power off
  • TES-2950

    LCR Trms Multimeter

    • Variable-frequency drive (VFD) V & Hz measurement.
    • Data hold, Auto hold & Peak hold mode.
    • Max/Min/Avg record mode.
    • Relative value display.
    • Frequency Count (Auto-Ranging).
    • Temperature type K, J measurement.
    • Inductance & Capacitance measurement.
    • 20MHz TTL logic check.
  • TES-1162

    Thermo / Hygro / Barometer

    • 1.8%RH high Accuracy Humidity measurement
    • Triple LCD displays Barometric pressure,
      Temperature, and Relative humidity
    • Absolute humidity, Mixing ratio and Enthalpy reading
    • Water vapor pressure and Water saturation pressure reading
    • Pressure trend and tendency (P3h) reading
    • Heat Index and Humidex reading
  • TES-1337B

    Lux Intensity Meter

    • Application:Street Lighting,tummel lighting,etc.
    • Luminous intensity(cd)=Lux x Distance²
    • Spectral correction factor function (include LED)
    • User calibration function (CAL)
    • Dual Display, 4-digit LCD reading.
    • Spectral Sensitivity close to CIE photopic Curve.
    • Measuring Levels Ranging 0.01 to 200.0 Klux, 0.001 to 20.00 Kfc,
      Autoranging 5 step.
    • Accurate and Instant response.
    • Luminous intensity measurement.
    • Data Hold function.
    • Data memory and read function.
    • Point - average function.
    • Auto power off function.
  • PROVA-A1/PROVA-A3

    DC/AC Clamp Meter

    • Five kinds of Dual display:
      Hold + Average
      Max + Min
      ΔMax + ΔMin
      Peak Max + Peak Min
      Δ Peak Max + Δ Peak Min
    • With Backlight
    • Auto Range: V, A, Resistance, Capacitance and Temperature.
    • Auto-Power-off function (30 min)
    • Ideal for works in crowded switch box or cable areas
  • TES-3100

    VIBRATION METER

    • Measures acceleration, Velocity and displacement
    • RMS, EQ PEAK and EQ P-P measurement
    • Wide range of vibration measurement by using different sensitivity of accelerometers
    • Maximum/Minimum record function
    • Earphone output for detecting noise in machine components
    • Manual memory stores up to 99 data
  • TES-660A /TES-660

    Micro Noise Dosimeter (Badge Type)

    • No Mic. Extension Cable required.
    • Lightweight and small size
    • Rechargeable battery
    • Calculates all the popular noise dose parameters  Wide dynamic range from 70 to a full 140dB
    • Measures simultaneously 3dB, 4dB, 5dB or 6dB exchange rates
    • Intrinsically safe (660A)
  • TES-3013 / TES-3014

    Digital Clamp Meter

    • Category: CAT II 1000V , CAT III 600V
    • Capacitance measurement 2000µF.
    • Variable-frequency drive VFD voltage & Current measurement.
    • ACA: 600A (3013), 1000A (3014)
    • Peak / Data Hold.
    • Frequency Count / Diode Check.
    • Continuity Buzzer.
  • TES-1339P

    Photosynthesis Light Quantum Meter

    • Autoranging 5 steps and conversion to µmole/m²/s (PPFD: Photosynthetic Photon Flux Density).
    • Integral illuminance measurement and conversion to mole/m²/d (Daily light integral).
    • Luminous intensity measurement.
    • Point - average function.
    • User calibration factor (CAL) and spectral correction factor (SCF) function. (include LED)
    • Time-hold function.
    • Dual Display, 4 digit LCD reading.
    • Spectral Sensitivity close to CIE photopic Curve.
    • Accurate and Instant response.
    • Data Hold function.
    • Data memory and read function.
    • Reference value stored for relative or
      percentage deviation measurement.
    • Ripple measurement for STRAY + LIGHT function.
    • Comparator function.
    • Auto power off function.
    • Auto datalogging & USB interface.
  • PROVA 1660

    Transformer Turns Ratio Meter

    • Measurements of 1Φand 3ΦTransformer/VT/CT Turns Ratio.
    • VT/PT ratio 0.8~10000, CT ratio 0.8~2000.
    • Graphical and Literal Illustration of Measurements and Connections with Large Back-lighted Dot Matrix 240 x 128 LCD. Display Test Data with Nameplate Transformer Values for Easy Interpretation.
    • Ten Test Frequencies (50~400Hz).
    • Display Turns Ratio, Deviation, Secondary Output, Excitation Voltage and Current, Phase Angle and Nameplate Transformer/VT/CT Values in one page for easy transformer quality interpretation.
    • Check for Live Test Points, Short Circuit, Open Circuit, and Reverse Polarity before Each Measurement. Message is displayed to Warn Users (But, checking is not performed once measurement starts).
    • Store 4096 Files of Transformer Nameplate Values (VT/PT/CT, 1Φ/3Φ, Test Frequency, Primary and Secondary Voltages or Ratio, RCF) and Measuring Data.
    • 9 types of 3Φ Windings Connections pre-installed for easy user selection.
    • Wireless Blue Tooth Communication with PC.
    • Select Filter to Remove Field Noise (Slow, Normal, Fast).
    • Disable or Enable Auto-Power-Off with Programmable Time.
    • Built-in calendar clock.
      Records with Date and Time Stamp.
    • Powerful Lithium Battery (3400mAH) with built-in Charging Circuit.
    • User Programmable RCF (Reference Correction Factor, 0.99~1.01) to Correct Accuracy within 1% Error.
    • Friendly File System for Easy On-site Data Retrieval and Nameplate Values Management.
    • PC Application Software included.
  • TES-3910

    Trms Clamp Meter (DC/AC 1000A)

    • Capacitance measurement 1000µF
    • Variable-frequency drive (VFD) V & Hz measurement.
    • Lo-Z voltage measurement to drain ghost voltages.
    • Check 3Φ phase sequence.
    • True RMS reading on AC and DC+AC mode.
    • Inrush current measurement.
    • A measurement for HVAC flame sensors.
    • mV measurement range to interface with other accessories.
    • Crest Factor & Harmonic ratio measurement.
    • Data hold, Auto hold & Peak hold mode.
    • Max/Min/Avg record mode.
    • Data memory & read function.
  • TES-1160 / TES-1161

    Thermo / Hygro / Barometer

    • Triple LCD displays Barometric pressure,
      Temperature, and Relative humidity.
    • Dew point and Wet bulb temperature reading.
    • Absolute humidity, Mixing ratio and Enthalpy reading.
    • Water vapor pressure and Water saturation pressure reading.
    • Pressure trend and tendency (P3h) reading.
    • Heat Index and Humidex reading.
    • MAX/MIN with Time Stamp.  Comparator function.
    • Alarm output function.
    • Auto power off function.
    • Data Hold function.
    • LCD backlight control function.
    • Manual data memory and read function.
    • Auto data logger function. (1161)
    • USB Interface. (1161)
  • TES-1150/TES-1151

    Digital Sound Level Meter

    • 0.1dB resolution.
    • Range from 30 to 130dB.
    • Maximum hold function.
    • A, C, Z frequency weightings.
    • A, C, Z peak hold function.
    • Fast, Slow and Impulse dynamic characteristic models.
    • AC/DC output jack.
    • Back-screw for tripod fixture.
    • Micro-USB (1151)
    • Auto data memory microSD CARD 4GB. (1151)
  • TES-2900

    True RMS MULTIMETER

    • Variable – frequency drive (VFD) V & Hz measurement.
    • Lo – Z voltage measurement to drain ghost voltages.
    • Check 3 phase sequence.
    • Voltage harmonic ratio measurement.
    • Smart ohm for ground resistance measurement.
    • Data hold & Auto hold mode.
    • Max/Min/Avg record mode.
    • Relative value display.
    • Frequecy count. (Auto-Range)
    • Temperature type K, J measurement.
    • Capacitance measurement.
    • Data memory & read function.
  • TES-5321 / TES-5322

    PM2.5 Air Quality Monitor (read directly)

    • Simple tool for air dust measurements (indoor)
    • Direct reading field air pollution degree
      No need for mobile phones to download data from cloud, no Internet Traffic problem,Easy use battery or AC adaptor to power the meter
    • Accurate Temperature and Humidity measurements
    • Mixed-gas VOCs(Volatile Organic Compounds) measurements,with high sensitivity to H2, C2H5OH,C4H10 and CH4 gas(TES-5322)
    • PM2.5 MAX/MIN with time stamp function
    • Health index(0-9) detection and alarm , six-color LED indication air quality index category
      Application:
    • Provide people with safety and health indoor environment
    • Portable to monitor any environment air quality
    • Investigate the effectiveness of different strategies to reduce particulates
    • Air quality investigations
  • TES-1358E

    Sound Analyzer

    • Compliant with IEC 61672-1 class 1 standard.
    • Real-time 1/1-Octave and 1/3-Octave analysis.
    • Measurement can be started by internal or external trigger.
    • Comparator output to trigger external devices.
    • Super high – contrast backlight TFT – LCD color display.
    • Dynamic range of 90dB.
    • AC and DC outputs.
    • Data transfer using USB.
    • micro SD CARD 4GB.
  • TES-5200

    Particle Mass Counter

    • Particle mass & particle counter in a single handheld unit.
    • Six mass ranges and eight particle sizes.
    • User K-factors setting for special particulate with different densities.
    • Integrated temperature / humidity sensor (no need for external add-on).
    • Flow rate 2.83 L / minute (0.1 CF / minute).
      ‧ Rechargeable battery provides up to 4 hours of continuous operation (charge time 2.5 hours).
      ‧Buffer function allows storing and redisplay of up to 500 measurement data sets.
      ‧SD storage device.
  • TES-5110

    Particle Counter

    • Six particle size channels : 0.3μm, 0.5μm, 1.0μm, 2.0μm, 5.0μm, 10μm
    • Integrated temperature / humidity sensor (no need for external add-on).
    • Flow rate 2.83 L/minute (0.1 CF / minute).
    • Rechargeable battery provides up to 4 hours of continuous operation (charge time 2.5 hours).
    • Buffer function allows storing and redisplay of up to 500 measurement data sets.
    • SD storage device.
  • TES-1358C

    Sound Analyzer Real Time 1/1 & 1/3 Octave band Analysis

    • Super high – contrast backlight TFT – LCD color display.
    • Compliant with IEC 61672-1 class 2 standard
    • Real-time 1/1-Octave and 1/3-Octave analysis.
    • Measurement can be started by internal or external trigger.
    • Comparator output to trigger external devices.
    • Data transfer using USB.
    • Dynamic range of 90dB.
    • Real time clock with calendar.
    • AC and DC outputs.
    • micro SD CARD 4GB.
  • TES-137

    Luminance Meter

    • Dual Display, 4-digit LCD reading.
    • Spectral Sensitivity close to CIE photopic Curve.
    • Measuring Levels Ranging 0.001 to 1999k cd/m2, 0.001 to 580.0k fL, Autoranging 7 step.
    • Accurate and Instant response.
    • Luminance ratio A/B, deviation %A,different B-A and peak luminance measurements.
    • User calibration factor and color-correction functions.
    • Accumulation luminance measurement.
    • Max/Min/AVG function.
    • Backlit function.
    • Comparator function.
    • Data Hold function.
    • Data memory and read function.
    • Data logger function.
    • USB Interface.
  • TES-136

    CHROMA METER

    • Triple Display, 4-digit LCD reading.
    • LED Color Bin select function (x,y) or (Tcp,Δuv).
    • User calibration function.
    • User reference value setting function.
    • Illuminance maximum/minimum measurement function.
    • Data Hold function.
    • Data memory and read function.
    • Data logger function.
    • USB Interface.
  • TES-3900/TES-3901

    Clamp Meter/Trms Clamp Meter

    • Variable-frequency drives (VFD) V & Hz measurement.
    • LoZ voltage measurement to drain ghost voltages.
    • Check 3 phase sequence.
    • Motor Inrush current measurement.
    • True RMS reading on AC and DC+AC mode. (3901)
    • uA measurement for HVAC flame sensors. (3901)
    • mV measurement range to interface with other accessories. (3901)
    • Crest Factor & Harmonic ratio measurement. (3901)
    • Data hold, Auto hold & Peak hold mode.
    • Max/Min record mode.
    • Data memory & read function.

Electronic Temperature Instruments Driver Jobs

  • 2017/07/25TAF Calibration Laboratory Authentication
  • 2016/10/06TES-3100 /3101/3102 VIBRATION METER
  • 2015/07/21TES-3910 Trms Clamp Meter